Basics
Secure default configuration
The device comes with a secure configuration and has hardened firmware settings that prevent unauthorized access to the system.
The device may only be operated in an environment suitable for production machines with appropriately secured physical access and within an appropriately secured network (e.g. B. ISO 27001 or equivalent).
Passwords
Note:
Change the device password when setting up the device (see chapter "Change device password").
Firmware and security updates
When setting up the device, check if new firmware updates are available.
Also, note that the device needs to be restarted after installing a firmware update.
Attention:
If you disable automatic firmware updates, the device will no longer receive security updates automatically.
Available updates are displayed on the local diagnostics page, but in this case they must be installed manually (see chapter "Firmware update of the sR Bridge").
GDPR
The GDPR-compliant remote service connection ensures that all data is transmitted securely and encrypted.
This ensures the protection of personal information against unauthorized access. This complies with the legal data protection requirements.
Note:
Homag must have explicit consent to the collection and processing of data.
In addition, appropriate security measures must be taken to prevent misuse or unauthorized access.
Logging & Protokollierung
There are system events that require continuous logging.
.png?sv=2026-02-06&spr=https&st=2026-09-22T01%3A47%3A06Z&se=2026-09-22T01%3A58%3A06Z&sr=c&sp=r&sig=bl4G1MQJKRF2HNpnCMYaXIHo7GDc6ElQvkOAJ9jZplc%3D)
Note:
These log entries are not deleted during a system restart.
Log entries of system events older than six months are automatically deleted.
A factory reset deletes all log entries.
In this case, the system reset is recorded as a new, first event in the log.
The log can be accessed from the local diagnostics page under System Information
Example system events are:
Component | System Event | Triggers |
|---|---|---|
Firmware update | Perform firmware updates | Local diagnostics page, Auto-update |
Enable auto-updates / Disable | Local Diagnostics Page | |
Reset firmware | Local Diagnostics Page | |
Configuration Update | New configurations from of the cloud | Local diagnostics page, Auto-Update (Initial Customer commissioning) |
System Service | Perform network settings | Local Diagnostics Page |
Change password | Local Diagnostics Page | |
Enable SSH Connection | Local diagnostics page, HOMAG Service USB Stick | |
Enable Cloud Connector / Disable | Local Diagnostics Page | |
On factory settings reset (after deleting of the minutes) | Local Diagnostics Page |