In addition to retrieving the status of the HOMAG , diagnostics in the local network can also be used to make certain settings on the device. It is also possible to install firmware updates or restart the HOMAG CUBE via diagnostics in the local network.

How do I connect to local diagnosis?

1. Readout hostname of the HOMAG CUBE:

  • Take a look at the nameplate on the CUBE

  • Write down the hostname (starting with "HOMAG-IoT...")

2. Connect to local diagnostics via a browser

  • Open your Internet browser (recommended "Google Chrome" or "Microsoft Edge") via a computer that is on the same network as the HOMAG CUBE. Open your internet browser (recommendation "Google Chrome" or "Microsoft Edge") via a computer that is in the same network as the HOMAG CUBE.

  • Enter the host name of the CUBE in the address bar of the browser (preceded by http:// ).

    Example: http://HOMAG-IoT-1234565562

3. After successful entry, the "local diagnosis" opens.

How do I register for local diagnosis?

Prerequisite: The local diagnostics must already be open via the Internet browser in the local network (see "How do I connect to the local diagnostics?")

1. Reading the password of the HOMAG CUBE:

  • Take a look at the nameplate on the CUBE

  • Write down the individual password (10 digits)

  • Enter the password via the local diagnostics already open in the browser.

  • Select the menu item "Login" on the home page.

  • Enter the password you wrote down earlier and click on "Login".

  • After successful entry, new diagnostic areas open in the local diagnostics.

How do I restart the HOMAG CUBE?

Requirements:

1. Select the "Restart" function

  • In the local diagnostics, navigate to the menu item "System reboot".

  • Confirm the restart.

2. The HOMAG CUBE is restarted.

Attention: It can take up to 90 seconds for the CUBE to boot up again and continue its operation.

What are the setting options?

Requirements:

1. Changing the password

  • Select the "Change Password" menu item.

  • First, enter the current password (see nameplate). Then set your new, individual password, enter it and confirm it. Attention: The following guidelines apply to the assignment of the new password:

    • Min. 10 characters, max. 30 characters

    • Min. 1 uppercase letter, 1 lowercase letter and 1 digit

2. Start the serviceRemote connection

  • Select the menu item "TeleService".

  • In the "ISN Info" section, select the "Start ISN TeleService" action and confirm with "OK".

  • After about 30 seconds, the info should switch from "Disconnect" to "Connected".

3. Installing a firmware update

4. Enabling/Disabling the SSH Service

5. Download the system log files

6. Changing the time synchronization